Buy Ready Portacabins – Online Store كرفانات جاهزة للتسليم الفوري Click to view ready units • اضغط لعرض الكرفانات الجاهزة
Sale!

Fire Rated Prefab Security Portacabin – 1 Room (6m x 3.6m) | UAE

Original price was: 17.000,00 د.إ.Current price is: 15.000,00 د.إ.

Delivery price is per cabin (max 12m x 3.6m). For more cabins, please place separate orders. Entry permits for our trailers, workers & Equipment, and the Site must be accessible for normal road trailers or crane to the exact offloading point.
To Be Provide By Client: Entry permits for our trailers, workers & Equipment, and the Site must be accessible for normal road trailers or crane to the exact offloading point. CICPA and Security Area- All Excluded
Supply and installation none-reinforcement concrete foundation size 400x400x400mm CICPA and Security Area all excluded.
Product total
Options total
Grand total
Pay a deposit of 50%

Delivery: within 10 working days from the date of advance payment

Fire-rated prefab security portacabin manufactured using LGS system.

Single room unit suitable for security guards, site entrances, and control points.

Factory-built cabin, ready to install, compliant with UAE site requirements.

Description

This fire rated prefab security portacabin is designed for security guard rooms,

site entrances, access control points, and temporary site facilities across the UAE.

The unit is manufactured using Light Gauge Steel (LGS) framing system, providing

excellent structural strength, fire resistance, and durability in harsh site

conditions.

With a compact 1-room layout and size of 6m x 3.6m, this security portacabin is

ideal for projects requiring quick deployment and reliable on-site presence.

Typical applications include:

• Security guard cabins

• Site access control rooms

• Temporary security offices

• Industrial and construction sites

Key Features:

• Fire rated prefab construction

• LGS steel structure

• Factory built and ready to install

• Suitable for UAE climate conditions

• Custom modifications available upon request

Delivery, crane offloading, and foundation works are not included unless agreed

separately based on project location.

TECHNICAL SPECIFICATIONS OF FIRE RATED PREFABRICATED BUILDINGS
(COLD FORMED STEEL FRAMING SYSTEM)

1

BASE SKID

1.1

Civil Works- Foundation 400x400x400mm (high) will be provided by the client as per the
approved design.
Steps will be provided by the client for entrance/ Exit areas. Closing under
the cabin excluded

1.2

Base skid: The steel base skid shall be constructed
from 
IPEAA 120X64 MS I Beam, as full perimeter beams and cross
members as per design.

1.3

Lifting eyes are provided at intermediate points along the perimeter beams

1.4

Anti-corrosive: Perimeter
beams shall be coated with one coat of 
red oxide
primer and painted with two coats of Alkyd-based enamel paint. 
(Brand: RAK
Paints or eqv.)

2

FLOOR & FINISHES

2,1

Floor Frame: C89x38x0.6mm LGS Joists fixed to the base skid as per design

2.2

Floor Decking: One Layer of 18mm thick Cement
fibreboard (non-combustible)
 fixed to floor frame as per drawing.

2.3

Floor finish in Dry Area:
Supply and installation of 1.5mm PVC on 18mm thick cement fibre board
floor.

50mm high PVC
skirting shall be provided. Color: off-white/ brown

Floor finish in Wet Area: 1.5mm thick PVC vinyl sheet
(Colour: Beige) fixed on 18mm thick cement fibreboard floor and wet area
floor joints heat welded for better waterproofing.  Brand: Wonderfloor – India or Eqv.

3

WALL FRAMING & FINISHES

3.1

Wall Framing: Cold-formed steel
profile framing-roll forming machine 
C89x38x0.6mm

Wall Insulation: 50mm thick Glass wool insulation with 12 Kg/m3
density.

3.2

External
Cladding: 
6mm thick
cement fibreboard finished with Medium Textured emulsion paint in an off-white
colour. (Brand: RAK Paints or eqv.)
External wall joints shall be covered by 6mm thick CFB joint strips.

3.3

Internal
Cladding:

Dry Area: 12mm thick gypsum board, fixed to cold-formed steel wall framing.
Joints shall be covered with 6mm thick Cement fibre board Joint strips.
Wet area: 6mm thick cement fibre board (non-combustible) fixed
to cold-formed steel wall framing. Joints shall be covered with 6mm thick
Cement fibre board Joint strips.

3.4

Internal
Finishing

Dry Area:  emulsion paint (off-white color)
applied to gypsum board.
(Brand: RAK Paints or eqv.).
Wet area: Enamel paint (white color) applied to cement fiber
board.
(Brand: RAK Paints or eqv.).

4

ROOF

4.1

Roof
Covering: 
Single skin
GI, Polyester coated 0.40mm thick profile sheets shall be fixed on GI Stud
purlins as per drawing. Roof sheet Colour: RAL 9002

Roof overhangs/parapet/Gutter/fascia/Downpipes are not considered in our
offer.

4.2

Trusses: Trusses are from cold-formed steel sections
-roll forming
machine 
C89x38x0.6mm

5

 CEILING

5.1

Ceiling: 12mm thick gypsum board, finished with
fine texture, good quality white color interior paint. (Brand: RAK
 Paints or eqv.).

Ceiling Joints shall be covered by 6mm thick CFB joint strips.

Ceiling clear height shall be approx. 2.35m

6

DOORS

6.1

Entrance Door with Accessories: aluminum door frame with or without
glass, as per choice, handle, and lock case shall be provided as per shown in
drawing. Door color: white
Single Door Size: 900mmx 2100mm / Double Door Size: 1800mmx 2100mm

6.2

Internal Doors / Toilet Doors: Flat
single flush doors with paper honeycomb core and PVC laminated finish.
Door Colour:  White
Internal Room Doors: 900x2100mm & Toilet Doors: 700x2100mm

6.3

Internal Door Accessories:
Door Lock system:  Mortice lockset with
cylinder and SS door handles shall be provided for all internal doors and
Single cylinder with thumb turn latch shall be provided for internal toilet
doors. Brand: “Godrej” or Eqv.

7

WINDOWS

7.1

External
Windows:
 Powder
coated aluminium frame (Non thermal break), with 6mm thick clear glass.
(Single glazing),One Sliding one fixed window.
Window Frame color: RAL 9010.
Window Size: 900mm x 900mm

7.2

Exhaust Window: Fixed window
with Aluminium framing and 6mm thick obscure glass as per drawing. Window
Frame colour: RAL 9010.

8

ELECTRICAL

8.1

Electrical supply is single-phase 230V, 50Hz/60Hz as
per design.

8.2

Electrical Final Distribution board (Consumer unit)
shall be provided with 63Amp 2P 100mA ELCB Incomer and SP MCB’s outgoings as
per design Brand: Hager or eqv.
MD, SUMDB power cabling up to Internal FDB are not
included in our offer.

8.3

Concealed PVC conduits shall be provided for
wiring.  Brand: Deco duct or eq.

8.4

PVC insulated Copper wires from NCI or
eq.

8.5

Light Fixtures:
• 1x 40W LED Panel Surface mounted Light fittings for Office Rooms.
Brand: MILANO or eq.(subject as per drawing)
• 1X20W LED Light fittings batten type for dry area. Brand: VETO INNOVA – UAE
or eq.
• 1X9W (W/P) LED bulkhead light for all external doors. Brand: EMKAY-VETO or
eq

8.6

 Switch /
sockets 13A single/twin shall be provided as per BS standard design.
Brand: Edison or eq. (White Range)

8.7

Provision for water heater shall be provided only
for pantry. Supply & installation of water heater shall be done by
client.

9

HVAC

9.1

Split
AC provision:

Power outlets (32A 3P PVC isolator wired with 1 C 6 Sqmm + ECC) for Split AC
units.
Brand – Milano or eqv.
Supply and Installation of Air conditioning units are not considered in our
offer.

9.2

Exhaust fans are provided as shown in drawing.
(6″dia window mounted cord operator type). Brand: 
Milano or eq.

10

PLUMBING

10.1

PPR pipes shall be used for the hot water and
cold-water distribution and Sewage lines are UPVC pipes.

10.2

N/A

10.3

N/A

11

TELE / DATA CONTAINMENTS ONLY

12.1

PVC conduits shall be provided for Tele/Data point
as per drawing.

Block wiring, Networking, sockets, junction boxes and system installation
shall be done by others.

 

EXCLUSIONS: TO BE PROVIDED BY CLIENT:

1

Site Work:

Foundation,
Scaffolding, Ground leveling, backfilling, landscape, paving, Soil testing,
De-watering, Demolition & Cleaning of Existing structure or Debris,
Entrance steps & skirting below caravan.

2

Site entry:

Entry permits (CICPA/CNIA – Security Permits) for our trailers, workers & Equipment’s and Site must be
accessible for normal road trailers.

3

Lifting:

Crane + lifting
tools

4

Furniture:

Wardrobes,
cabinets & other furniture, etc.

5

Accessories:

Window blinds,
Canopies, etc..

6

Structural:

Design
calculation, All third-party inspections, and tests

7

Electrical:

All external
Electrical connections, Cables, SUMDB & related wiring, MDB & related
wiring, Data & Telephone, Earthing system, IT works, CCTV, External lighting,
External Power Socket, HVAC, Cooking Utensils,

Generator, any
authority approvals.

8

Plumbing:

Embedded
Drainage, External Connections, Manholes, Storage Tanks, Pump.

9

Mechanical:

Fire Fighting
& Fire alarm Systems, etc.

Approvals:

Civil defense,
Municipality, and all other permits.

Additional information

Weight ,3000 kg
Dimensions 3600 × 3600 × 2600 cm
Usage

Security Cabin, Site Offices, Guard Room

Unit Type

Security Cabin, Guard Room, Site Office

Number of Rooms

1 Room

Toilet / Pantry

No Toilet I No Pantry

Window Size (cm)

160 x100 QTY 1 I 100X100 QTY 1

Overall Size

6 m x 3.6 m

Fire Rating

Fire Rated

Structure System

LGS 89 X 38 X 0.6 mm (Light Gauge Steel)

Wall Thickness

107 mm I 113 mm

Roof Type

PPGI Sheet VI: 38/200 + Glass Wool Insulation + Aluminum Foil

Floor Type

Cement Board + Vinyl

Delivery Condition

EX Factory I Factory Built I Ready to Install

Customization

Available on Request

Electrical / Sanatory

Included I Plug and Play Cabin

Wall /Roof Insulation

Glass Wool 12 KG/M3

Shipping Policy

Price is EX-Factory only.

Transportation and delivery are not included unless selected and paid separately.

السعر الموضح هو سعر المصنع فقط (EX-Factory).


لا يشمل السعر أي نقل أو توصيل أو تنزيل.

يمكن ترتيب التوصيل عند الطلب ويتم احتسابه بشكل منفصل في حال اختياره.

Refund Policy

Customers may submit customization requests as order notes.

All requests are subject to technical review.

Additional charges may apply, and a separate payment link may be issued if required.

يمكن للعميل إضافة أي طلب تعديل أو تخصيص من خلال الملاحظات أثناء إتمام الطلب.


سيتم مراجعة جميع طلبات التخصيص من قبل الفريق الفني.

في حال تطلّب التعديل أعمالًا إضافية أو تغييرات أساسية، قد يتم إرسال رابط دفع منفصل أو عرض سعر معدل للموافقة عليه قبل التنفيذ.


لن يتم البدء في التصنيع إلا بعد اعتماد النطاق النهائي وسداد أي مبالغ إضافية – إن وجدت.


Cancellation / Return / Exchange Policy

All orders are considered final once production has started.

Cancellations after production commencement are not permitted.

Advance payments are non-refundable after production initiation.

يمكن إلغاء الطلب فقط قبل بدء أعمال التصنيع.


بعد بدء التصنيع، لا يمكن إلغاء الطلب بسبب شراء المواد الخام

وبدء العمليات التصنيعية وحجز موارد المصنع.


تُعد الدفعة المقدّمة غير قابلة للاسترداد بعد بدء التصنيع.


يجب تقديم طلب الإلغاء كتابيًا وهو خاضع للمراجعة والموافقة.